Currently if you use copydb to copy the local database from one replica set member to another replica set member, the oplog entries get copied over without applying the associated writes to the user data. This could cause your oplog and your data to get out of sync, potentially causing serious problems.
- is related to
-
SERVER-8511 Live oplog can be dropped