Type: Bug
-
Resolution: Done
-
Priority: Critical - P2
-
Affects Version/s: None
-
Component/s: Networking, Security
-
Minor Change
-
ALL
Starting with a custom bind_ip, which does not resolve should not be permitted.
$ ./mongod ... --bind_ip=foo ... [initandlisten] options: { net: { bindIp: "foo", http: { RESTInterfaceEnabled: true, enabled: true } },... [initandlisten] getaddrinfo("foo") failed: nodename nor servname provided, or not known [initandlisten] waiting for connections on port 27017 [websvr] getaddrinfo("foo") failed: nodename nor servname provided, or not known [websvr] admin web console waiting for connections on port 28017
As you can see above, even though the bind_ip is specified, the server still listens on all addresses which could be a serious security or ops problem.
$ netstat -na | grep LIST tcp4 0 0 *.28017 *.* LISTEN tcp4 0 0 *.27017 *.* LISTEN
If there is any error resolving, or listening on any of the bind_ip (addresses) the server should fail to initialize just like if the port is already used or not allowed to be used for the user/process trying to listen on it.
Here are some examples of similar errors:
// IP specified not valid on the host [initandlisten] listen(): bind() failed errno:49 Can't assign requested address for socket: 127.1.1.1:27017 [websvr] listen(): bind() failed errno:49 Can't assign requested address for socket: 127.1.1.1:28017 ... shutdown // Protected port specified [initandlisten] listen(): bind() failed errno:13 Permission denied for socket: 0.0.0.0:80 ... shutdown
Having a better, and consistent, error message for all these cases might be nice as well, but first and foremost, the system should be stable and secure.
- is duplicated by
-
SERVER-15656 Improve bind_ip handling of badly formatted Internet address numbers
- Closed
- related to
-
SERVER-15630 Empty net.bindIp listens to all interfaces
- Closed
-
SERVER-15656 Improve bind_ip handling of badly formatted Internet address numbers
- Closed