RPL 6 07/17/15
These ops are not thrown away and can lead to a deadlock between the applier and producer threads. The applier thread believes it has finished and is waiting for the producer thread to signal that it has paused. Meanwhile, the producer thread is waiting for the op that arrived late (which the applier is unaware of) to be applied.
- is related to
-
SERVER-21474 Remove stepdown_while_draining test and failpoint
- Closed