Waiting for opTime or majority read concern is not interruptible

XMLWordPrintableJSON

    • Type: Bug
    • Resolution: Done
    • Priority: Major - P3
    • 3.3.14
    • Affects Version/s: 3.3.12
    • Component/s: Replication
    • None
    • Fully Compatible
    • ALL
    • Sharding 2016-10-10
    • 0
    • None
    • 3
    • None
    • None
    • None
    • None
    • None
    • None

      The code in ReplicationCoordinatorImpl::waitUntilOpTimeForRead which waits for majority read or an opTime does not use the interruptible way to wait on a condition variable and because of this internal operations might get stuck.