Type: Bug
-
Resolution: Done
-
Priority: Major - P3
-
Affects Version/s: 3.2.7
-
Component/s: Replication
-
Fully Compatible
-
ALL
-
v3.4, v3.2
-
TIG 2017-02-13
-
(copied to CRM)
Scenario:
During the process of Changing the Size of the Oplog, one step is to Restart a Secondary in Standalone Mode on a Different Port.
After the change, when the node is Restarted again as a part of the replica set, the fatal assertion may be triggered. The fatal assertion itself is covered under SERVER-23390.
However, the issue in this case is caused by the behavior of tmp.agg_out temporary collections which are cleaned after the restart of the mongod server.
[repl writer worker 14] writer worker caught exception: :: caused by :: 26 Failed to apply insert due to missing collection: { ts: Timestamp 1476945662000|9194, t: 112, h: 3665423956733067926, v: 2, op: "i", ns: "db1.tmp.agg_out.81", o: ... [repl writer worker 14] Fatal Assertion 16360
- has to be done before
-
SERVER-27285 Add a jsCore passthrough with a replset that periodically SIGKILLs a secondary
- Closed
- related to
-
SERVER-23390 Missing collection during replication causes shutdown