Type: Improvement
-
Resolution: Done
-
Priority: Major - P3
-
Affects Version/s: None
-
Component/s: Replication
-
None
-
Fully Compatible
-
v3.4
-
Repl 2017-03-06
-
0
reconfig can occasionally lead to the primary stepping down. This means that the guarantee we thought SERVER-20844 gave us, of being a stable replicaset with node 0 as primary, is not always guaranteed. To address this, we should call awaitNodesAgreeOnPrimary() and then make sure that node 0 is the primary. If it is not, we should step up node 0 to primary. In PV1 we can use replSetStepUp on node 0 to accomplish this. In PV0, we can repeatedly call replSetStepDown on the primary with a high step down timeout until node 0 is elected. At that point we can call replSetFreeze on every node with a freeze timeout of 0 to allow them all to run for election immediately if they want to.
- related to
-
SERVER-27839 Allow for step downs during reconfig in ReplSetTest initiate
- Closed
-
SERVER-28376 ReplSetTest.initiate() should call awaitReplication before requesting node 0 to step up as primary
- Closed