Don't hold database or collection locks during oplog truncation

    • Fully Compatible
    • v4.0, v3.6, v3.4
    • Storage NYC 2018-06-18, Storage NYC 2018-07-02, Storage NYC 2018-07-16

      Some customers are sensitive to the short stalls that can be caused by oplog truncation, which can be a moderately heavy operation. We could mitigate this issue by providing a parameter to tune the amount of oplog data truncated in a single operation.

            Assignee:
            xiangyu.yao@mongodb.com Xiangyu Yao (Inactive)
            Reporter:
            bruce.lucas@mongodb.com Bruce Lucas (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            17 Start watching this issue

              Created:
              Updated:
              Resolved: