Type: Bug
-
Resolution: Unresolved
-
Priority: Major - P3
-
None
-
Affects Version/s: None
-
Component/s: Replication
-
Replication
-
ALL
-
Repl 2018-07-30, Repl 2018-08-13, Repl 2018-08-27, Repl 2018-09-10
-
17
For secondary batch application, the ApplyBatchFinalizer is used to advance optimes after application of an oplog batch completes. We currently use the ApplyBatchFinalizerForJournal for durable storage engines and the ApplyBatchFinalizer for non-durable storage engines, which only updates the lastApplied optime. On primaries, for non-durable storage engines, the replication system keeps the lastDurable optime up to date wth the lastApplied optime, since the lastDurable optime has no functional meaning on a non-durable storage engine. It seems we should be keeping this behavior consistent between primaries and secondaries, so we should update the lastDurable optime on batch application on non-durable storage engines.
- related to
-
SERVER-22728 if journaling is disabled, update durableOpTime when appliedOpTime updates
- Closed
-
SERVER-37943 Enable replica set transactions for the inMemory WT storage engine
- Closed
-
SERVER-38685 Startup warning if In-Memory SE is used and writeConcernMajorityJournalDefault is true
- Closed