TenantOplogApplier operations must be interruptible on step down / step up

XMLWordPrintableJSON

    • Type: Bug
    • Resolution: Fixed
    • Priority: Major - P3
    • 5.0.0-rc3, 5.1.0-rc0
    • Affects Version/s: None
    • Component/s: None
    • Fully Compatible
    • ALL
    • v5.0
    • Repl 2021-06-28
    • 167
    • None
    • 3
    • None
    • None
    • None
    • None
    • None
    • None

      The TenantOplogApplier write noop methods currently acquire the RSTL in IX mode when reserving slots and waiting on writers and the writer threads do the same. The associated opCtx must be interruptible on step down and step up.

            Assignee:
            Vishnu Kaushik
            Reporter:
            Vishnu Kaushik
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved: