Type: Improvement
-
Resolution: Fixed
-
Priority: Major - P3
-
Affects Version/s: None
-
Component/s: None
-
None
-
Fully Compatible
-
Storage - Ra 2022-01-10, Storage - Ra 2022-01-24
-
3
Context:
A WiredTiger system log component hierarchy was introduced in SERVER-61744. In lieu of a nice abstraction to reconfigure the WiredTiger connection when a LOGV2 component setting changed, an intermediate solution used in SERVER-61744 was to block any changes to the WiredTiger hierarchy at runtime. This is un-ideal in the long term. It would be preferable to allow for the WiredTiger LOGV2 hierarchy to be updated a runtime. This ticket will look to implement a solution that make runtime reconfiguration possible.
Definition of Done:
A solution to enable the propagation of log component settings to the WiredTiger connection at runtime could roughly involve the following:
- Create a LogConfig interface owned by each KVEngine implementation.
- Have an implementation of the LogConfig interface in the WiredTigerKVEngine.
- This having access to the WiredTiger connection interface, with which it can map the updated LOGV2 components to an appropriate WiredTiger verbose configuration string.
- Call the LogConfig method of the KVEngine instance when handling the reconfiguration of the LOGV2 components.
- depends on
-
SERVER-61744 Handle a new WiredTiger system log component hierarchy in LOGV2
- Closed