Fail point must be enabled on new primary before step up in range_deletion_ordering_with_stepdown.js

XMLWordPrintableJSON

    • Fully Compatible
    • ALL
    • v6.0
    • Sharding EMEA 2022-06-13
    • 13
    • None
    • 3
    • None
    • None
    • None
    • None
    • None
    • None

      In range_deletion_ordering_with_stepdown.js, the hangBeforeDoingDeletion failpoint is enabled after the new primary steps up. This can allow an extra batches to be deleted before the orphan count assertions can run.

      The failpoint needs to be enabled on the new primary before step up.