Type: Bug
-
Resolution: Fixed
-
Priority: Critical - P2
-
Affects Version/s: None
-
Component/s: None
-
Storage Engines 2018-09-10
-
v4.0, v3.6
'_StringException' was detected during long running unit testing on 'aws-build-test2', which passed the same test before.
http://build.wiredtiger.com:8080/job/wiredtiger-test-unit-long/3486/console
====================================================================== ERROR: test_timestamp04.test_timestamp04.test_rollback_to_stable(nolog.row-smallcache) (subunit.RemotedTestCase) test_timestamp04.test_timestamp04.test_rollback_to_stable(nolog.row-smallcache) ---------------------------------------------------------------------- _StringException: lost connection during test 'test_timestamp04.test_timestamp04.test_rollback_to_stable(nolog.row-smallcache)' ---------------------------------------------------------------------- Ran 17675 tests in 1744.825s
- is duplicated by
-
WT-4290 Rollback to stable test failed in test_timestamp04.py
- Closed