Uploaded image for project: 'WiredTiger'
  1. WiredTiger
  2. WT-6374

Ensure upgrade after an unclean shutdown works

    • Type: Icon: Bug Bug
    • Resolution: Fixed
    • Priority: Icon: Major - P3 Major - P3
    • WT10.0.0, 4.4.0-rc10, 4.7.0
    • Affects Version/s: None
    • Component/s: None
    • None
    • Storage - Ra 2020-06-15

      We have a report that upgrade after an unclean shutdown is reporting an error after durable history. That is running a busy system using MongoDB 4.2, shutting down with a kill -9 and then starting up with MongoDB and having recovery run. The error seen was:

      "message":"[1591208760:588748][30679:0x7f40955f6b80], file:collection-2-4036376553196063132.wt, txn-recover: __txn_op_apply, 287: operation apply failed during recovery: operation type 4 at LSN 840600/103502080: No such file or directory"}
      

        1. 42log
          14 kB
        2. db42secondary.tar.gz
          1.14 MB
        3. lsn734976.txt
          226 kB

            Assignee:
            luke.pearson@mongodb.com Luke Pearson
            Reporter:
            alexander.gorrod@mongodb.com Alexander Gorrod
            Votes:
            0 Vote for this issue
            Watchers:
            13 Start watching this issue

              Created:
              Updated:
              Resolved: