5
-
Storage - Ra 2021-02-08, Storage - Ra 2021-02-22
Executing the eMRCf_runner.sh tests with more than 7 growth iterations and enableMajorityReadConcern set to true results in a SIGAbort when shutting down the primary.
The time to recover ("WiredTiger Opened" log message duration) is very long in comparison to a normal shutdown.
Typically the reported restart durations for a normal shutdown were less than 2 seconds. In the case where there was an abnormal shutdown, durarions were of the order of 1000 seconds.
- is related to
-
SERVER-54441 Long Oplog Recovery times after SigAbort failures
- Blocked